-
Smoke + CO Technical Specifications
This article explains all the specifications of the sensor including design, physical characteristics, size, operations, and Regulatory Listings. In addition, it will explain everything that should be included with that Smoke + CO sensor. What is included in the package? Wireless combination Smoke, Heat, and Carbon Monoxide Alarm with mounting base Installation guide (ADP0812) Pack of Screws and Anchors 2x CR123A batteries Technical Specifications and characteristics Battery: 2x CR2032 (Or 2 Energizer EL123AP Lithium batteries) Battery Life: Up to 5 years Life Expectancy: 10 years Weight: 10.5 oz. (Including battery) Size Dimensions: 5” diameter X 2.75” Height Broadcast Frequency: 345 MHz Color: White Audible Signal: 85 dBA Operating Temperature: 40℉-100℉ (4.4℃-37.8℃) Operating Humidity: 10%-90% RH Non-Condensing Supplementary Heat Rating: 135℉ Sensor Signal Range to Panel: 100 Feet UL Listing: Intertek ETL listed to UL268 with supplemental heat detection, UL 2075, ULC S529 with supplementary heat detection, and ULCS588 standards.…Read More -
Smoke + CO General Troubleshooting
This article addresses some of the more common concerns you may come across and how to fix them. If your question isn’t addressed in this document, please call us at 855-268-3669 and we can help My panel and sensor are reporting a Loss of supervision? Loss of supervision means the panel is having a difficult time trying to communicate with the Smoke + CO device. Please try the suggestions listed in the article- Smoke + CO Loss of Supervision. My sensor is reporting a Low Battery. How do I change the Batteries? The sensor’s battery life runs roughly 2.5-5 years depending on usage. If the panel reports that low battery you can see how to change it in the article- How to change the Smoke + CO batteries. What does the Beeping/Flashing Light Combination mean? Below is a chart that lists the different possibilities for flashing lights and chirping noises. Please count the seconds between flashes and chirps to determine what alert it is reporting. How long is the life of the device? The detector has a 10-year life expectancy. Once it has reached the end of life, it will chirp every 48 seconds and flash the YELLOW LED 5 times every 12 seconds. The detector will need to be replaced. The sensor is triggering a false alarm. For false alarm assistance, please refer to this article. If there are multiple false alarms occurring with the same device, please call us at 855-268-3669. We would want to look into why it is triggering and offer you the best solution to fix it.…Read More -
Smoke + CO Detector Loss of Supervision
Understanding Smoke + CO Issues It is important to regularly test and maintain all system sensors. A low battery or abnormal damage to the sensor can cause irregular activity, including loss of supervision. Loss of supervision is an automatic diagnostic the system uses to verify that sensors are wireless communicating properly. Other contributing factors that can cause loss of supervision are distance to the panel, large mirrors, large fish tanks, large metal objects, or concrete/mortar barriers and objects. Step by Step Instructions When your sensors are experiencing a LOSS of SUPERVISION we need to identify if it is being caused by: The distance of the sensor from the panel and/or interference A low battery or A bad sensor DO NOT RESET THE PANEL To test if your sensor is too far from the panel: Change the location of the panel to be closer to the potentially malfunctioning sensor (within 10-20 feet). This is a temporary troubleshooting step. You do not have to keep your panel next to the sensor. Test the sensor to reconnect it to the panel. Wait 48 hours to see if the issue persists. Deleting the sensor and re-adding it back: If your issues persist, delete the sensor from the system. Re-add it back into the system. If the sensor will not clear or continue the Loss of Supervision, follow the next steps. If deleting and adding back the sensor does not fix your issue: Try replacing the batteries. Test the sensor to reconnect it to the panel. Wait 48 hours to see if the issue persists.…Read More -
How to Change the Smoke + CO Detector Batteries
If you have received a Smoke + CO Low Battery message on your panel, you will need to replace the battery promptly to ensure the device continues to function properly. Information to order replacements can be found in our article, How to Order Replacement Batteries. How to Replace the Batteries Disarm your Cove panel before you begin this process. Open the Smoke + CO Detector by turning the detector counterclockwise until the back cover releases. Carefully remove the existing batteries. Pay close attention to the orientation of the (+) and (-) sides of the battery in the device. Wait 20 seconds before inserting the new batteries. Place 2 new CR123A batteries in the detector. Wait 20 seconds while the Smoke + CO Detector resets. Turn the Smoke + CO clockwise back into place on the mounting plate. To ensure that your Smoke + CO Detector is functioning properly, run a Complete Sensor Signal Test. Enter into your Settings Click on System Click Test System Click the greyed out Test button You will only have to test your Smoke + CO, however, you have the option to run a complete sensor test. Once your sensor verifies with the monitoring station, you can exit the test by pressing the Home button on the panel.…Read More -
How to add a Smoke + CO Detector
This article explains the step by step instructions to install the Smoke + CO detector. Step by Step Instructions Click "Settings" on the top right-hand corner of the panel touch screen. Enter your four-digit Master Code. Click "Sensors" Click "Smoke" Click "Smoke + CO" Click "Add New Sensor" Remove Pull Tab from the sensor. Trigger the sensor by pressing the Fire button. This button is the button on the left-hand side. (The panel will indicate the sensor has successfully been added.) Press "Continue" Select a name for the new sensor Select "Next" 9. If you have additional Smoke + CO sensors to add, select "Add More Smoke + CO" otherwise select "Done Adding Smoke + CO"…Read More -
How it works - Smoke + CO Detectors
This piece of equipment is critical for life and property protection. Our Smoke + CO alerts you and the monitoring station automatically in the event of a fire or lethal levels of Carbon Monoxide. If your alarm is disarmed, this sensor remains ready to diligently protect you and your loved ones. Smoke FAQ We recommend placing at least one detector near your bedrooms where people sleep and one per each level of your home. The Smoke + CO is particularly important for those with limited mobility or other health concerns that may impede their ability to escape the home quickly and safely. Smoke As the Smoke portion of this sensor measures particulates in the air, this is a major reason we recommend NOT installing the sensor near a vent or area of the home that experiences drafts. Carbon Monoxide FAQ The Carbon Monoxide portion has a chemical inside that when it reacts to CO, it causes a chemical reaction inside the device triggering an alarm. Carbon monoxide is an odorless, colorless gas that can be fatal to humans and pets. It cannot be discerned by your senses, so we recommend using this sensor to protect against this potential hazard. Carbon monoxide is produced when fuels burn-in: Cars Generators Stoves Grills Fireplaces Gas Ranges Furnaces Gas-powered hot water heaters We recommend placing at least one sensor on each level of your home. The Smoke + CO detector is particularly helpful for those with household pets that may be alone during the day. Light and Chirp Indicators The Smoke + CO has a built-in LED indicator and chirp system that will report to you of any alarms or faults happening with the device. Please refer to the table below to see what your Smoke + CO is reporting.…Read More -
Smoke + CO False Alarms
It is important to regularly test and maintain all system sensors. A low battery or abnormal damage to the sensor can cause irregular activity. Troubleshooting False Alarms Make sure the detector is a Cove sensor and not a pre-existing Smoke + CO detector Make sure the sensor was not installed in any of the following places: Directly above a sink Directly above a stove or within 5 feet of any cooking appliance Next to a door or window that would be affected by drafts, like an extractor fan or air vent Where airflow would be obstructed by curtains or furniture Where dirt or dust could collect and block the sensor Where the sensor could be knocked, damaged, or accidentally removed Verify the sensor has not expired (a sticker or label on the outside of the device has an expiration date) Replace the Battery (2x CR123A)…Read More -
Installing Smoke + CO Detectors
Step by Step Guide If you are adding new equipment to your alarm system, make sure you have already added the Smoke + CO to your alarm system before you install the piece of equipment. Common Installation Locations Bedroom Hallway Main Living Spaces Avoid Do not install Smoke + CO Detectors in the following areas: Within 5 feet of any cooking appliance Next to a door or window that would be affected by drafts In or below a cupboard Outside the home Where airflow would be obstructed by curtain, partition, or furniture Where dirt or dust could collect and block the detector Where it could be knocked, damaged, or inadvertently removed Best Practices Within 10 feet of sleeping areas and in bedrooms that contain fuel-burning appliances If the appliance or room is not normally used, such as a boiler room, the detector should be placed just outside the room so the alarm can be heard. Ceiling Mount-place the detector at least 12 inches from any wall (measured from the closest outside edge of the detector). The green area below indicates proper placement. Wall Mount- place the detector at least as high as a light switch and at least 6 inches from the ceiling (measured from the closest outside edge of the detector). The green area below indicates proper placement. Installing Smoke + CO Consult the user manual included in your packaging for detailed installation, testing, and maintenance instructions. If you are going to use the adhesive: remove the adhesive backing. Press firmly and hold in place for 30 seconds. If you are going to use the screws: Once a suitable location has been identified, install the mounting base on the ceiling or wall using the 2 screws and anchors provided. Fit the Detector on the mounting base and turn clockwise until the detector clicks into place and the alignment notches are aligned.…Read More